EFM
Range of Iron and Manganese Filters
The
EFM Range of Iron and Manganese Filters has been designed
to provide an effective treatment for iron and manganese
contamination.
The
filters require water with a minimum pH value of 6.8
and any application that has water with a pH value below
this will need pre-treatment.
All
units use potassium permanganate as a regeneration chemical.
A small tank is also included in with the filter for
storage of the chemical. This tank automatically controls
the chemical consumption and requires replenishment
approximately every 12 months.
The
units feature a time clock controlled automatic backwashing
multiport valve mounted on a GRP Pressure Vessel.
These
units are supplied with the media in separate bags which
are charged into the filter vessel during commissioning.
An initial charge of potassium permanganate is included.
We
are able to offer a full installation and after sales
service scheme on all equipment.
The
flow rates quoted below are for guidance purposes only.
|
|
EFM
10 |
EFM13 |
EFM16 |
EFM21 |
| Max
Flow Rate |
2m³/hr |
2.5m³/hr |
3m³/hr |
4m³/hr |
| Min
Flow Rate |
0.1m³/hr |
0.2m³/hr |
0.3m³/hr |
0.4m³/hr |
| Filter
Diameter |
254mm |
331mm |
407mm |
535mm |
| Filter
Height |
1570mm |
1583mm |
1849mm |
1849mm |
| Connections |
3/4
“ BSP |
3/4
“BSP |
1”
BSP |
1”BSP |
All
Filters require a 240-volt 50Hz 13Amp socket and a drain
for backwash waters capable of handling a flow of up
to 1m³/hr.
All
filters bypass raw water to service during backwash.
· Optional
bypass closedown valves are available.
· Level
and pump control systems are available to work in conjunction
with these systems.